IRMA TruPoint Blood Analysis System
IRMA TruPoint offers bedside testing that is accurate, reliable and self-contained.
Accurate
- Precise results within two minutes
- Lab quality accuracy
- Comprehensive menu
- Custom correlation
Reliable
- Single-use cartridge for maintenance free convenience
- Self-contained calibrant in each cartridge
- Real-time, automatic electronic quality control
Self-Contained
- All-in-one design is lightweight and battery-operated
- On-board thermal printer documents results and test notes
- Interactive touch screen
Watch the IRMA TruPoint Training Video here.
Consumable
-
Room Temperature Storage (Creatinine cartridge requires refrigeration)

- Single-use cartridge
- Calibration with every test
- No external reagents or gases required
- Closed sample introduction system
- Easy to use
Cartridge Test Menu - Measured Values:
| CC | BG | H3 | H4 | GL | CR | LA | |
| pH | ♦ | ♦ | |||||
| pCO2 | ♦ | ♦ | |||||
| pO2 | ♦ | ♦ | |||||
| Na+ | ♦ | ♦ | ♦ | ♦ | |||
| K+ | ♦ | ♦ | ♦ | ♦ | |||
| Cl- | ♦ | ♦ | |||||
| iCa | ♦ | ♦ | |||||
| Glu | ♦ | ||||||
| BUN | ♦ | ||||||
| Hct | ♦ | ♦ | ♦ | ||||
| Creatinine | ♦ | ||||||
| Lactate | ♦ |
Cartridge Test Menu - Calculated Values:
| CC | BG | H3 | H4 | GL | CR | |
| HCO3- | ♦ | ♦ | ||||
| TCO2 | ♦ | ♦ | ||||
| BEecf | ♦ | ♦ | ||||
| BEb | ♦ | ♦ | ||||
| O2SAT | ♦ | ♦ | ||||
| iCa(N) | ♦ | |||||
| tHb | ♦ | ♦ | ♦ |
Specifications
Reportable Ranges Measured:
| pH | 6.000-8.000 pH units |
| pCO2 | 4.0-200.0 mmHg (0.53-26.66 kPa) |
| pO2 | 20.0-700.0 mmHg (2.67-93.33 kPa) |
| Na+ | 80.0-200.0 (mM, mEq/L) |
| K+ | 1.00-20.00 (mM, mEq/L) |
| Cl- | 30.0-150.0 (mM, mEq/L) |
| iCa |
0.20-5.00 mM (0.40-10.00 mEq/L; 0.80-20.00 mg/dL) |
| BUN | 3-150 mg/dL (1.1-53.5 mM) |
| Glucose | 20-500 mg/dL (1.1-27.8 mM) |
| Hct | 10.0-80.0% (.100-.800 SI) |
| Creatinine | 0.2-12 mg/dL (18-1061 µmol/L) |
| Lactate | 0.30-12 mmol/L (2.7-108 mg/dL) |
General Specifications:
| Minimum Blood Sample Size |
0.2mL from a syringe 0.125mL from the IRMA TruPoint Capillary Collection Device |
| Data Storage |
200 patient test records 150 liquid QC records 100 electronic QC / Temperature test results |
| Cartridge Storage Temperature | 15-30°C / 59-86°F |
|
Creatinine Cartridge Storage Temperature |
2-8°C / 35.6-46.4°F |
Literature
Other
Optional Accessories:
- Barcode reader
- idms™ data management software
- Device Set configuration software
Connectivity:
Interface connectivity available through:
- AegisPOC™
- RALS®-Plus
- TELCOR QML®
Quality Control:
- Liquid Quality control performed using RNA® Medical Controls. For detailed information, visit RNA Medical Controls